An open fireplace works differently from a wood stove. A stove connects straight to the liner. An open fireplace has no outlet: the smoke rises from the firebox, through the damper and the smoke chamber, and only then into the flue. That changes two things: the size of the liner and how you connect it at the bottom.

Size the liner to your fireplace opening, not to a stove

With a stove, the liner matches the stove outlet. With an open fireplace, the liner must be large enough for the whole opening. The rule in the US building code: a round liner needs a cross-section of at least 1/12 of the fireplace opening.

Measure the width and height of the opening in inches and multiply them. Then check the table:

LinerCross-sectionFits a fireplace opening up to
7 inch 38 sq in about 460 sq in (for example 21 x 22 in)
8 inch 50 sq in about 600 sq in (for example 24 x 25 in)
10 inch 78 sq in about 940 sq in (for example 36 x 26 in)
12 inch 113 sq in about 1,350 sq in (for example 45 x 30 in)

 

Most open fireplaces are 30 to 36 inches wide, so they need a 10 or 12 inch liner. A liner that is too small cannot carry the smoke away, and the smoke comes back into the room. More on sizing in our guide to chimney flue diameter.

A large round liner also has to fit inside your existing flue. With insulation around it, a 10 to 12 inch liner needs 11 to 13 inches of clear space. Many older chimneys have rectangular flue tiles that are too narrow for that; there, an oval or rectangular liner is used.

Where the liner ends: the bottom plate

At the bottom, the liner ends on a bottom plate: an 18 x 18 inch steel plate with a collar that clamps to the liner. You set the plate at the top of the smoke chamber, where the old flue tiles begin, and seal it in place with refractory cement. Do not run the liner down into the firebox, and do not end it just above the fire. The smoke chamber funnels the smoke into the liner and keeps the fire from smoking into the room.

The damper

To get the liner past the throat, you often have to remove the old damper. You can then fit a top-sealing damper on top of the chimney. It closes the flue when the fireplace is not in use and keeps cold air and rain out.

Insulation

An old chimney built for an open fireplace is large, so the flue gas cools quickly on the way up. Insulating the liner keeps the gas warm, which gives you a steady draft and less creosote. See insulated vs non-insulated chimney liners.

What you need

  • Flexible stainless steel liner, in the size from the table
  • Bottom plate
  • Top plate and rain cap
  • Insulation kit
  • Refractory cement for the bottom plate
  • Optional: a top-sealing damper

What we supply, and what we do not

From us you get 7 and 8 inch 316Ti flexible liners with the matching top plate, rain cap and insulation kit, in our chimney liner range. These suit a small fireplace opening, up to about 460 sq in for 7 inch and about 600 sq in for 8 inch.

We do not currently supply bottom plates, liners larger than 8 inch, oval or rectangular liners, refractory cement or top-sealing dampers. For a standard-size open fireplace you will need to source these elsewhere, for example from a local chimney supply store.

Installing the liner itself works the same as for a stove; see our chimney liner installation guide.