Determine the Height of the Stove Pipes
Take a measurement from the stove up to the middle of the opening in the wall.
You only need to be close with your measurements here, not exact. Our black stove pipes cannot be cut to size so you will need one of our telescoping lengths to complete your installation. This gives you lots of "play" in your measurement.
Stove pipes must be kept at least 18″ away from any combustible materials.
For the vertical-rise options, the stove adapter and 90-degree elbow together provide approximately 11 inches of vertical rise. They are not used when the stove exits horizontally from the rear.
Between them, you can install:
A variable length pipe (strongly recommended): 38–70 inches (effective vertical length: 36–68 inches). Easy to install.
A fixed straight length:
12 inches – effective length: 10 inches
18 inches – effective length: 16 inches
24 inches – effective length: 22 inches
Fixed pipe lengths provide less adjustment. The wizard combines them with a telescoping section where adjustment is required. Do not cut any component unless its product instructions specifically allow it.
For a standard top-outlet installation, measure horizontally from the centerline of the vertical stovepipe to the point where the single-wall stovepipe connects to the Class A adapter.
For a direct rear exit, measure from the stove’s rear outlet to the Class A connection point.
Do not measure all the way to the wall. Single-wall stovepipe must stop before the wall and remain at least 18 inches from combustible materials.
Choose the closest range. The telescoping stovepipe provides adjustment. Keep the horizontal run as short as practical. If your measurement falls outside the available ranges, please contact us before ordering.
Measure the complete wall thickness from the finished inside surface to the finished outside surface.
The wizard accounts for the wall thickness, the inside clearance, approximately 4 inches provided by the tee branch and an adjustable outside wall distance of 2–7 inches.
The standard wall thimble fits walls from approximately 6–10 inches. It can be shortened for thinner walls. For walls thicker than 10 inches, please contact us before ordering.
Follow the 3-2-10 rule:
Choose the closest available height that is equal to or greater than your required measurement. Question E will determine whether an Extended Roof Brace is required.
Also see out blog on "Height of a Chimney"
Measure from the highest support point—normally the top wall bracket or roof flashing—to the top of the chimney.
If the unsupported length would exceed 10 feet, contact us before ordering. This wizard does not calculate such installations.
14 Days Guaranteed Return14 day cooling off period whereby your goods can be sent back to us
Limited Lifetime WarrantyOur no quibble promise to you
Lowest Price GuaranteeCheaper elsewhere?; We'll beat it by 5%
Selected products
Our wood stove pipe kits through the wall are complete class A UL103HT stainless steel chimney systems for safe exterior-wall venting, not partial pass-through parts.
If you’re comparing configurations or exploring alternatives, see our complete wood stove pipe kits to plan the right setup.
Garage Chimney Pipe Kits Through the Wall
You should choose a through the wall wood stove pipe kit when a roof penetration isn’t possible or would create structural or layout challenges.
Garages, basements, cabins, sheds and workshops frequently rely on this configuration because the stove sits near an exterior wall. Other factors that make this option more practical are:
When your stove is operating, hot exhaust gases rise naturally and create draft inside the chimney. In a through-the-wall setup, the stove connects to a short interior pipe that directs exhaust toward the exterior wall.
At the wall, the system transitions to a class A insulated chimney pipe. From there, the chimney runs vertically outside the building, where proper height supports stable draft and consistent airflow.
MANUAL Installation Guide
Successful through-the-wall systems start by mapping the entire chimney path first, rather than assembling parts one at a time.
1. The layout begins at your stove’s collar;
2. Runs through a short interior stove pipe section;
3. Transitions at the wall and then continues vertically outside the building.
Keeping the interior run short and direct helps you keep draft before the wall pass-through. The chimney height is then built upward after the tee, based on draft needs, building height and exterior exposure. For step-by-step guidance, check our wood stove chimney pipe installation resources.
1. Start by planning the chimney height from the tee outlet upward, since exterior vertical rise plays a major role in draft and smoke evacuation. Many installers mention the 3-2-10 rule as a general guideline, but it should always be checked against local requirements and your specific layout.
2. Wall brackets aren’t decorative hardware. Spacing them roughly every 6 to 8 feet helps stabilize the chimney against wind and movement.
3. The base wall support carries the chimney’s vertical load, while brackets prevent lateral stress on the wall thimble and tee.
4. Use high-temperature sealant only where the instructions specify, not everywhere joints meet.
5. Respect the required clearances around interior stove pipe sections, especially if you’re using a single-wall pipe.
6. Before the final assembly, double-check your measurements, wall thickness and clearances, as small planning errors can affect draft, alignment and long-term reliability.
Passing a chimney through an exterior wall brings high flue temperatures close to framing, insulation and siding. That’s why building codes require insulated chimney systems at all wall penetrations.
A single-wall stove pipe is designed only for short interior connections. It must not pass through a wall because it:
Our class A chimney pipes are built specifically for wall and ceiling penetrations. Its insulation:
A stove pipe and class A chimney pipe serve different roles. Using each in the right location supports safe, code-compliant and reliable stove performance.
A wood stove pipe kit through the wall is a complete Class A UL103HT stainless steel chimney system designed to vent a wood stove safely through an exterior wall rather than the roof. It combines insulated chimney pipe, transition components, supports and termination parts into one coordinated system.
This approach is common in residential and off-grid settings where interior vertical runs are not possible. Instead of mixing individual parts, our full kit through the wall ensures compatibility, proper clearances and a continuous venting path from your stove to the outside.
Both options work when planned correctly. Venting through the roof usually allows a straighter vertical run, which can simplify draft when your layout permits it.
Venting through the wall is often chosen when roof penetration is not practical due to structure or interior layout. You should keep in mind that each approach has different considerations for chimney height, exterior exposure and support.
Yes. Through-the-wall wood stove chimney kits are designed specifically for wall penetrations when installed correctly. Safety depends on using a Class A insulated chimney pipe at the wall pass-through and for the exterior run. Proper insulation, clearance control and structural support are what make these systems safe for long-term use.
No. A single-wall stove pipe must not pass through a wall, ceiling or any combustible structure. Interior stove pipe is only intended for open interior runs where clearances allow. The transition to Class A insulated chimney pipe must happen before the wall penetration to control surface temperatures and protect surrounding materials.
You should seal the wall with a wall thimble, not by filling gaps with sealant. The thimble respects the required clearances and creates a protected pass-through.
Sealant is only used where the installation instructions specify, typically at approved joints or interfaces. If you use the wrong sealing methods, you can compromise clearances and safety.
The correct size is determined by your stove collar diameter, which is the inner diameter of the chimney pipe connection on your stove. In most residential installations, this will be either 6 inch or 8 inch.
6 inch exterior wood stove chimney pipes are the most common choice for moderate-output stoves used in garages, cabins, workshops, basements and smaller homes. It balances airflow and draft well when exterior chimney height is properly planned.
8 inch exterior wood stove chimney pipes are typically required for larger stoves with higher heat output. Because it moves a greater volume of exhaust, sufficient vertical rise outside the wall is essential for stable draft.
Reducing or increasing the diameter compared to your stove collar can lead to draft problems, smoke spillage and long-term performance issues. The chimney system you choose must match the stove's specified flue size.
Several issues show up repeatedly during through-the-wall installations. Here are some of the most common:
Mismatched pipe diameters can restrict airflow and reduce performance.
Chimneys that are too short often struggle with draft.
Incorrect assumptions about wall penetrations can lead to unsafe transitions.
Missing exterior support is another frequent mistake, because wall brackets and base supports are structural necessities, not optional accessories.