Many wood-burning stoves come with the choice of attaching the flue pipe to either a top or rear flue exit. From the stove, you can lead the chimney directly outside, run it upwards first and then outside, or take the chimney all the way through the house.
For the adaptor you have the following options:
Single to twin wall adaptor (also increasing adaptors)
This adaptor can be installed in two ways:
Single to twin wall continental adaptor
A continental twin wall adaptor creates an easy connection of twin wall flue pipe to any European model of stove.
This Continental Stove Adaptor is used if you have a European stove collar, as the sizes are slightly smaller than a standard 5" or 6" stove collar.
The distance can be calculated as: distance = G + E + D
G = distance heart of stove outlet - to- wall E = thickness wallD = distance outside wall - to - flue (usually 50mm, but can go up to 350mm in case you want to go along a overhanging roof, without using elbows)
If the distance is fixed (you can not move the stove forward or backward) you will most likely need an adjustable T135 piece. When you have some flexibility in the distance between stove and wall; you can do with a - cheaper - simple T135 piece.
Together with the T135 piece, we will add:- the 45 degree elbow - the wall sleeve. The wall sleeve is meant to slide through the wall and to be cut to length as required. Add mortar around outside of it or fireproof insulation.- 2 finishing plates, to cover the opening between the flue and the wall; both inside and outside.
You need a base support unit to that carries the weight of the outside flue. (A wall support only gives sidewards stability)
You can choose between:
- Base Support Bracket : Can carry the weight of maximum 5 m of flue
- Base Support: Can carry the weight of up to 12m of flue
Determine what the height (X) of the flue outside should be from the T upwards
Step 1: Determine the required height on the roof (M) see " Complete information" below.
Step 2: Calculate the total height of the flue (stove to rain cap)
Total height of the flue (Z) = M + L - KL = Height of the roofK = Height of the stove
Step 3: Calculate how many meters (X) of straight pipes are needed outside (above the T)
X = Z - V
Z = Total height of the flue (see step 2)V = height coming from the stove till the T (it is written top right in question 2 " ...."mm upwards")
Check: The total height (Z) from stove to end cap should be at least 3.5 meter. You do not need to have the exact height, a bit higher higher is also okay.
Within 600mm from the ridgeThe flue has to end minimum 600mm above the ridge.
More than 600mm from the ridgeThe distance between the cowl of the flue and the adjacent roof/wall/structure should be higher than 2.3 mtr.
For the height on the roof this means:
The minimum chimney height recommended for minimum performance of wood burning and multi fuel appliances is 4.5 m from the top of the appliance to the top of the chimney. In practice you 3.5m is often enough.
The distance between the cowl of the flue and the adjacent roof/wall/structure should be higher than 2.3 mtr.
Within 600mm from the ridge: Flue has to end minimum 600mm above the ridge.
The diagram below, taken from Document J (building regulations), shows the minimum flue discharge heights and positions for all wood burning and multi fuel applications.
In some cases, particularly when chimneys are towards the bottom of a sloping roof or at the eaves, it may be necessary to increase the chimney height above these minimum mandatory requirements. The reason for this is to clear pressure zones created by wind hitting the roof and nearby structures, like trees, which may interfere with the up draught required by the appliance or fire.
The maximum freestanding stack height above the roof for a traditional masonry chimney is 4.5 times the narrowest horizontal part of the chimney.In the case of stainless steel system chimneys, the manufacturer’s installation instructions should be consulted; however in most cases it will be around 3 metres. This measurement is taken from the last point where the chimney stack passes the through or past the edge of the roof up to the chimney capping or termination. Tall chimneys may need bracing, always consult the manufacturer for advice.
For buildings with flammable roofs such as felted, thatched, or shingle roofs the flue or chimney the regulations are different. The flue or chimney must terminate at a minimum1800mm above the combustible surface.
Type of Wall support
Normally the wall supports with a 50 - 70mm distance wall - flue are taken. To pass an overhanging roof, you can choose other distances.
Number of Wall supports
This depends on how many meters the flue goes along the wall. We recommend to use a wall support every 3 meter along the wall. So every 2 - 3 meter above the Base support; 1 wall support.
There are 2 types of cap to choose from:
Rain capWill keep vertical falling rain out of the flue. In case of side winds, rain will enter the flue. In case of a flue outside this is less of a problem, as it will not floote into the house.
All weather CowlKeeps rain out of the flue. Also blocks downwinds from entering your flue. Downwinds come from higher objects in the vicinity (up to 10mtr), and without this Cowl they will blow the smoke back into your house.
You need to support the flue over the roof if the free end becomes too long and requires additional support. We recommend to use a telescopic support if the free end is between 1,5m and 3m.
14 Days Guaranteed Return14 day cooling off period whereby your goods can be sent back to us
Warranty: From 10 years to a lifetimeOur no quibble promise to you
Selected products
Black Black with Offset St. Steel with Offset
This complete stainless steel twin wall flue kit is designed for straight external wall installations. It’s ideal when your stove is positioned against a wall and the flue pipe needs to run directly up along the outside of the building — without offset. Safe, certified, and suitable for both timber and brick walls.
The configurator on the right is preloaded for a straight wall flue system in stainless steel, without offsets. This is ideal for garden rooms, garages, and extensions where the flue can rise along a flat outer wall.
If this matches your situation, you can start right away.
Installation More products
Can I install this flue kit on any external wall? Yes. As long as you meet the required distances from openings and combustible materials, this kit is suitable for most external brick or timber walls.
Is this kit HETAS-compliant? Yes – all components are CE-certified and meet UK building regulations for twin wall flue systems.
What if I later need an offset?You can increase the distance from the wall to bypass the gutter. If that’s not possible, the Exterior Kits with Offset are designed for offset installations and includes the necessary supports. Choose the kit that fits your setup, or contact us if you’re unsure.
When you visit any website, it may store or retrieve information on your browser, usually in the form of cookies. This information does not usually identify you, but it does help companies to learn how their users are interacting with the site.
We respect your right to privacy, so you can choose not to accept some of these cookies. Choose from the different category headers to find out more and change your default settings.
These cookies are essential for the proper functioning of the website and cannot be disabled. They are usually set only in response to actions performed by you on our site, such as logging in, adding items to your shopping cart, or filling in forms. If you use our website, you accept these cookies.
These cookies are used to collect statistics to optimize the functionality of the site and deliver content tailored to your interests.
Marketing cookies are used to track visitors across websites. The purpose is to display ads that are relevant and engaging to individual customers and therefore more valuable to publishers and third-party advertisers.
These cookies are used to save userdata like login details and your shopping basked.